Introduction :
Chloride, in the
form of chloride (Cl ~) ion, is one of the major inorganic anions in water and
wastewater. The salty taste produced by chloride concentrations is variable and
dependent on the chemical composition of water. Some waters containing 250 mg C1~/L
may have a detectable salty taste if the cation is sodium.
On the other
hand, the typical salty taste may be absent in waters containing as much as
1000 mg/L when the predominant cations are calcium and magnesium.
The chloride
concentration is higher in wastewater than in raw water because sodium chloride
(NaCl) is a common article of diet and passes unchanged through the digestive
system. Along the sea coast, chloride may be present in high concentrations
because of leakage of salt water into the sewerage system. It also may be increased
by industrial processes.
A high chloride
content may harm metallic pipes and structures, as well as growing plants.
Selection of
Method
Six methods are
presented for the determination of chloride. Because the first two are similar
in most respects, selection is largely a matter of personal preference. The
argentometric method (B) is suitable for use in relatively clear waters when
0.15 to 10 mg Cl~ are present in the portion titrated. The end point of the mercuric
nitrate method (C) is easier to detect. The potentiometric method (D) is
suitable for colored or turbid samples in which color-indicated end points
might be difficult to observe. The potentiometric method can be used without a
pretreatment step for
samples
containing ferric ions (if not present in an amount greater than the chloride
concentration), chromic, phosphate, and ferrous and other heavy-metal ions. The
ferricyanide method (E) is an automated technique. Flow injection
analysis (G), an automated colorimetric technique, is useful for analyzing
large numbers of samples. Preferably determine chloride by ion chromatography (Section
4110). Chloride also can be determined by the capillary ion electrophoresis
method (Section 4140). Methods (C and G) in which mercury, a highly toxic
reagent, is used require special disposal practices to avoid improper sewage
discharges. Follow appropriate regulatory procedures (see Section 1090).
Sampling and
Storage
Collect
representative samples in clean, chemically resistant glass or plastic bottles.
The maximum sample portion required is 100 mL. No special preservative is
necessary if the sample is to be stored.
B. Argentometric
method
1. General
Discussion
a. Principle: In a neutral or
slightly alkaline solution, potassium chromate can indicate the end point of
the silver nitrate titration of chloride. Silver chloride is precipitated
quantitatively before red silver chromate is formed.
b. Interference:
Substances
in amounts normally found in potable waters will not interfere. Bromide,
iodide, and cyanide register as equivalent chloride concentrations. Sulfide,
thiosulfate, and sulfite ions interfere but can be removed by treatment with hydrogen
peroxide. Orthophosphate in excess of 25 mg/L interferes by precipitating as
silver phosphate. Iron in excess of 10 mg/L interferes by masking the end
point.
2. Apparatus
a. Erlenmeyer
flask, 250-mL.
b. Buret, 50-mL.
3. Reagents
a. Potassium
chromate indicator solution: Dissolve 50 g K2CrO4 in a little distilled
water. Add AgNO3 solution until a definite red precipitate is formed. Let stand
12 h, filter, and dilute to 1 L with distilled water.
b. Standard
silver nitrate titrant, 0.0141M (0.0141A1): Dissolve 2.395 g AgNO3 in
distilled water and dilute to 1000 mL. Standardize against NaCl by the
procedure described in 11 4b below; 1.00 mL = 500 fig Cl~. Store in a
brown bottle.
c. Standard
sodium chloride, 0.0141M
(0.0141AT): Dissolve 824.0 mg NaCl (dried at 140°C) in distilled water and
dilute to 1000 mL; 1.00 mL = 500 jjig Cr.
d. Special
reagents for removal of interference:
1) Aluminum
hydroxide suspension: Dissolve 125 g aluminum potassium sulfate or aluminum
ammonium sulfate, AIK(SO4)2-12H2O or A1NH4(SO4)2-12H2O, in 1 L distilled water.
Warm to 60°C and add 55 mL cone ammonium hydroxide (NH4OH) slowly with
stirring. Let stand about 1 h, transfer to a large bottle, and wash precipitate
by successive additions, with thorough mixing and decanting with distilled
water, until free from chloride. When freshly prepared, the suspension occupies
a volume of approximately 1 L.
2) Phenolphthalein
indicator solution.
3) Sodium
hydroxide, NaOH, IN.
4) Sulfuric
acid, H2SO4, IN.
5) Hydrogen
peroxide, H2O2,
30%.
4. Procedure
a. Sample
preparation: Use
a 100-mL sample or a suitable portion diluted to 100 mL. If the sample is
highly colored, add 3 mL A1(OH)3 suspension, mix, let settle, and filter. If
sulfide, sulfite, or thiosulfate is present, add 1 mL H2O2 and stir for 1 min.
b. Titration: Directly titrate
samples in the pH range 7 to 10. Adjust sample pH to 7 to 10 with H2SO4 or NaOH
if it is not in this range. For adjustment, preferably use a pH meter with a
nonchloride- type reference electrode. (If only a chloride-type electrode is
available, determine amount of acid or alkali needed for adjustment and discard
this sample portion. Treat a separate portion with required acid or alkali and
continue analysis.) Add 1.0 mL K2CrO4 indicator solution. Titrate with standard
AgNO3 titrant to a pinkish yellow end point. Be consistent in end-point recognition.
Standardize AgNO3 titrant and establish reagent blank value by the titration
method outlined above. A blank of 0.2 to 0.3 mL is usual.
5. Calculation
rag C1~/L =(A
- B) X TV X 35450/mL sample
where:
A — mL titration for
sample,
B = mL titration
for blank, and
N = normality of
AgNO3.
mg NaCl/L = (mg
Cr/L) X 1.65
6. Precision and
Bias
A synthetic
sample containing 241 mg C1~/L, 108 mg Ca/L, 82 mg Mg/L; 3.1 mg K/L, 19.9 mg
Na/L, 1.1 mg NO3--N/L, 0.25 mg NCV- N/L, 259 mg SO4 2~/L, and 42.5 mg total
alkalinity/ L (contributed by NaHCO3) in distilled water was analyzed in 41
laboratories by the argentometric method, with a relative standard deviation of
4.2% and a relative error of 1.7%.
7. Bibliography
HAZEN, A. 1889.
On the determination of chlorine in water. Amer. Chem. J. 11:409.
KOLTHOFF, I.M.
& V.A. STENOER. 1947. Volumetric Analysis. 2nd ed.
Vol. 2.
Interscience Publishers, New York, N.Y., pp. 242-245, 256-258.
PAUSTIAN, P.
1987. A novel method to calculate the Mohr chloride titration.
In Advances in
Water Analysis and Treatment, Proc. 14th Annu. AWWA Water Quality
Technology Conf., November 16-20, 1986, Portland, Ore., p. 673. American Water
Works Assoc., Denver,Colo.
C. Mercuric
Nitrate Method
1. General
Discussion
a. Principle'. Chloride can be
titrated with mercuric nitrate, Hg(NO3)2, because of the formation of soluble,
slightly dissociated mercuric chloride. In the pH range 2.3 to 2.8, diphenylcarbazone
indicates the titration end point by formation of a purple complex with the
excess mercuric ions. Xylene cyanol FF serves as a pH indicator and end-point
enhancer. Increasing the strength of the titrant and modifying the indicator
mixtures extend the range of measurable chloride concentrations.
b. Interference:
Bromide
and iodide are titrated with Hg(NO3)2 in the same manner as chloride. Chromate,
ferric, and sulfite ions interfere when present in excess of 10 mg/L.
2. Apparatus
a. Erlenmeyer
flask, 250-mL.
b. Microburet, 5-mL with
0.01-mL graduation intervals.
3. Reagents
a. Standard
sodium chloride, 0.0141M
(0.01417V): See Method B, H 3c above.
b. Nitric acid, HNO3, 0.1 AT.
c. Sodium
hydroxide, NaOH, 0.1 TV.
d. Reagents for
chloride concentrations below 100 mg/L:
1) Indicator-acidifier
reagent: The HNO3 concentration of this reagent is an important factor in
the success of the determination and can be varied as indicated in a) or b) to
suit the alkalinity range of the sample. Reagent a) contains sufficient HNO3 to
neutralize a total alkalinity of 150 mg as CaCO3/L to the proper pH in a 100-mL
sample. Adjust amount of HNO3 to accommodate samples of alkalinity different
from 150 mg/L.
a) Dissolve, in
the order named, 250 mg s-diphenylcarbazone, 4.0 mL cone HNO3, and 30 mg xylene
cyanol FF in 100 mL 95% ethyl alcohol or isopropyl alcohol. Store in a dark
bottle in a refrigerator. This reagent is not stable indefinitely.
Deterioration causes a slow end point and high results.
b) Because pH
control is critical, adjust pH of highly alkaline or acid samples to 2.5 ± 0.1
with 0.1/V HNO3 or NaOH, not with sodium carbonate (Na2CO3). Use a pH meter
with a nonchloride type of reference electrode for pH adjustment. If only the
usual chloride-type reference electrode is available for pH adjustment, determine
amount of acid or alkali required to obtain a pH of 2.5 ±0.1 and discard this
sample portion. Treat a separate sample portion with the determined amount of
acid or alkali and continue analysis. Under these circumstances, omit HNO3 from
indicator reagent.
2) Standard
mercuric nitrate titrant, 0.007 05M (0.0141/V): Dissolve 2.3 g Hg(NO3)2 or
2.5 g Hg(NO3)2-H2O in 100 mL distilled water containing 0.25 mL cone HNO3.
Dilute to just under 1 L. Make a preliminary standardization by following the procedure
described in 11 4a. Use replicates containing 5.00 mL standard NaCl solution
and 10 mg sodium bicarbonate (NaHCO3) diluted to 100 mL with distilled water.
Adjust titrant to 0.0141/V and make a final standardization; 1.00 mL = 500 |_ig
Cl ~. Store away from light in a dark bottle.
e. Reagent for
chloride concentrations greater than 100 mg/L:
1) Mixed
indicator reagent: Dissolve 0.50 g diphenylcarbazone powder and 0.05 g
bromphenol blue powder in 75 mL 95% ethyl or isopropyl alcohol and dilute to
100 mL with the same alcohol.
2) Strong
standard mercuric nitrate titrant, 0.0705M (0.141/V) Dissolve 25 g
Hg(NO3)2-H2O in 900 mL distilled water containing 5.0 mL cone HNO3. Dilute to
just under 1 L and standardize by following the procedure described in f 4b.
Use replicates containing 25.00 mL standard NaCl solution and 25 mL
distilled water. Adjust titrant to 0.141/V and make a final standardization; l.OOmL
= S.OOmgCr.
4. Procedure
a. Titration of
chloride concentrations less than 100 mg/L: Use a 100-mL sample or smaller
portion so that the chloride content is less than 10 mg.
Add 1.0 mL indicator-acidifier reagent. (The
color of the solution should be green-blue at this point. A light green
indicates pH less than 2.0; a pure blue indicates pH more than 3.8.) For most
potable waters, the pH after this addition will be 2.5 ±0.1. For highly
alkaline or acid waters, adjust pH to about 8 before adding indicator-acidifier
reagent.
Titrate with
0.0141 N Hg(NO3)2 titrant to a definite purple end point. The solution turns
from green-blue to blue a few drops before the end point.
Determine blank
by titrating 100 mL distilled water containing 10 mg NaHCO3.
b. Titration of
chloride concentrations greater than JOO mg/L: Use a sample portion (5 to 50
mL) requiring less than 5 mL titrant to reach the end point. Measure into a
150-mL beaker. Add approximately 0.5 mL mixed indicator reagent and mix well.
The color should be purple. Add 0.1 AT HNO3 dropwise until the color just turns
yellow. Titrate with strong Hg(NO3)2 titrant to first permanent dark purple.
Titrate a distilled water blank using the same procedure.
5. Calculation
(A - B) X N X
35450
mg C1-/L = - '-
mL sample
where:
A = mL titration
for sample,
B = mL titration
for blank, and
N = normality of
Hg(NO3)2.
mg NaCl/L = (mg
Cr/L) X 1.65
6. Precision and
Bias
A synthetic
sample containing 241 mg C1~/L, 108 mg Ca/L, 82 mg Mg/L, 3.1 mg K/L, 19.9 mg
Na/L, 1.1 mg NO3~-N/L, 0.25 mg NO2~-N/L, 259 mg SO4 2"/L, and 42.5 mg
total alkalinity/ L (contributed by NaHCO3) in distilled water was analyzed in
10 laboratories by the mercurimetric method, with a relative standard deviation
of 3.3% and a relative error of 2.9%.
7. Bibliography
KOLTHOFF, I.M.
& V.A. STENGER. 1947. Volumetric Analysis, 2nd ed. Vol. 2. Interscience
Publishers, New York, N.Y., pp. 334-335.
DOMASK, W.C.
& K.A. KOBE. 1952. Mercurimetric determination of chlorides
and
water-soluble chlorohydrins. Anal. Chem. 24:989.
GOLDMAN, E.
1959. New indicator for the mercurimetric chloride determination
in potable
water. Anal. Chem. 31:1127.
D.
Potentiometric method
1. General
Discussion
a. Principle: Chloride is
determined by potentiometric titration with silver nitrate solution with a
glass and silver-silver chloride electrode system. During titration an
electronic voltmeter is used to detect the change in potential between the two
electrodes. The end point of the titration is that instrument reading at which
the greatest change in voltage has occurred for a small and constant increment
of silver nitrate added.
b. Interference:
Iodide
and bromide also are titrated as chloride. Ferricyanide causes high results and
must be removed. Chromate and dichromate interfere and should be reduced to the
chromic state or removed. Ferric iron interferes if present in an amount substantially
higher than the amount of chloride. Chromic ion, ferrous ion, and phosphate do
not interfere.
Grossly contaminated samples usually require
pretreatment. Where contamination is minor, some contaminants can be destroyed simply
by adding nitric acid.
2. Apparatus
a. Glass and
silver-silver chloride electrodes: Prepare in the laboratory or purchase a
silver electrode coated with AgCl for use with specified instruments.
Instructions on use and care of electrodes are supplied by the manufacturer.
b. Electronic
voltmeter, to
measure potential difference between electrodes: A pH meter may be converted to
this use by substituting the appropriate electrode.
c. Mechanical
stirrer, with
plastic-coated or glass impeller.
3. Reagents
a. Standard
sodium chloride solution, 0.0141M (0.0141A/): See K 4500-a~.B.3c.
b. Nitric acid, HNO3, cone.
c. Standard
silver nitrate titrant, 0.0141A/ (0.0141A7): See 11 4500-C1-.B.36.
d. Pretreatment
reagents:
1) Sulfuric
acid, H2SO4, 1 + 1.
2) Hydrogen
peroxide, H2O2, 30%.
3) Sodium
hydroxide, NaOH, IN.
4. Procedure
a.
Standardization: The
various instruments that can be used in this determination differ in operating
details; follow the manufacturer's instructions. Make necessary mechanical
adjustments. Then, after allowing sufficient time for warm up (10 min), balance
internal electrical components to give an instrument setting of 0 mV or, if a
pH meter is used, a pH reading of 7.0.
1) Place 10.0 mL
standard NaCl solution in a 250-mL beaker, dilute to about 100 mL, and add 2.0
mL cone HNO3. Immerse stirrer and electrodes.
2) Set
instrument to desired range of millivolts or pH units. Start stirrer.
3) Add standard
AgNO3 titrant, recording scale reading after each addition. At the start, large
increments of AgNO3 may be added; then, as the end point is approached, add
smaller and equal increments (0.1 or 0.2 mL) at longer intervals, so that the
exact
end point can be
determined. Determine volume of AgNO3 used at the point at which there is the
greatest change in instrument reading per unit addition of AgNO3.
4) Plot a
differential titration curve if the exact end point cannot be determined by
inspecting the data. Plot change in instrument reading for equal increments of
AgNO3 against volume of AgNO3 added, using average of buret readings before and
after each addition. The procedure is illustrated in Figure 4500-C1~:1.
b. Sample
analysis:
1) Pipet 100.0
mL sample, or a portion containing not more than 10 mg Cl~, into a 250-mL
beaker. In the absence of interfering substances, proceed with H 3) below.
2) In the
presence of organic compounds, sulfite, or other interferences (such as large
amounts of ferric iron, cyanide, or sulfide) acidify sample with H2SO4, using
litmus paper. Boil for 5 min to remove volatile compounds. Add more H2SO4, if
necessary, to keep solution acidic. Add 3 mL H2C>2 and boil for 15 min,
adding chloride-free distilled water to keep the volume above 50 mL. Dilute to
100 mL, add NaOH solution dropwise until alkaline to litmus, then 10 drops in
excess. Boil for 5 min, filter into a 250-mL beaker, and wash precipitate and
paper several times with hot distilled water.
3) Add cone HNO3
dropwise until acidic to litmus paper, then 2.0 mL in excess. Cool and dilute
to 100 mL if necessary. Immerse stirrer and electrodes and start stirrer. Make
any necessary adjustments according to the manufacturer's instructions and set selector
switch to appropriate setting for measuring the difference of potential between
electrodes.
4) Complete
determination by titrating according to 11 4a4). If an end-point reading has
been established from previous determinations for similar samples and
conditions, use this predetermined end point. For the most accurate work, make
a blank titration by carrying chloride-free distilled water through the procedure.
5. Calculation
mg
(A - B) X N
X 35450
mL sample
where:
A = mL AgNO3,
B = mL blank, and
N = normality of
titrant.
6. Precision and
Bias
In the absence
of interfering substances, the precision and bias are estimated to be about
0.12 mg for 5 ing Cl~, or 2.5% of the amount present. When pretreatment is
required to remove interfering substances, the precision and bias are reduced
to about 0.25 mg for 5 mg Cl~, or 5% of amount present.
7. Bibliography
KOLTHOFF, I.M.
& N.H. FURMAN. 1931. Potentiometric Titrations, 2nd ed. John Wiley &
Sons, New York, N.Y.
REFFENBURG, H.B.
1935. Colorimetric determination of small quantities of chlorides in water. Ind.
Eng. Chetn., Anal. Ed. 7:14.
CALDWELL, J.R.
& H.V. MEYER. 1935. Chloride determination. Ind. Eng. Chem., Anal.
Ed. 7:38.
SERFASS, E.J.
& R.F. MURACA. 1954. Procedures for Analyzing Metal- Finishing Wastes. Ohio
River Valley Water Sanitation Commission, Cincinnati, Ohio, p. 80.
FURMAN, N.H.,
ed. 1962. Standard Methods of Chemical Analysis, 6th ed. D. Van
Nostrand Co., Princeton, N.J., Vol. I.
WALTON, H.F.
1964. Principles and Methods of Chemical Analysis. Prentice-
Hall, Inc.,
Englewood Cliffs, N.J.
WILLARD, H.H.,
L.L. MERRITT & J.A. DEAN. 1965. Instrumental Methods of Analysis, 4th ed.
D. Van Nostrand Co., Princeton, N.J.
Comments
Post a Comment