Skip to main content

Water Analysis : To Estimate The Amount Of Ammonical Nitrogen (NH3-N) of Given Sample By Finate Method



INTRODUCTION:

In waste water, the forms of nitrogen are of great interest in order of decrealing oxidation state. Nitrite, nitrate, ammonia & organic nitrogen all there forms of nitrogen as well as N2 are biochemically interconvertabale & are components of N2 cycle. they are of great interest for many reasons.

Ammonia is present naturally in surface & wastewater. Its conc. is generally low in ground water because it absorbs sail particles & clays & is not reached by from oils. It is produced largely by de amination of organic N2 containing compounds by hydrolysis of some water treatment plants Ammonia is added to react with chlorine to form combine fluorine residual ammonia conc. Encountered in water very strong less than 10 mg ammonia nitrogen per liter. In some natural surface & ground water to more than 30 mg per liter in some waste water.

Various methods available for the estimation of ammonia nitrogen are:
1.       Ammonia selective electrode method (0.03-1400mg NH3.N per lit.)
2.       Finite method (0.6mg NH3-N per lit.)
3.       Automated finite method (0.02-2mg NH3-N per lit.)
FINATE METHOD:

PRINCIPLE:
                 
An intensely blue compound endophenol is formed by the reaction of ammonia, hypochloride & phenol catallized by sodiumpruside. This blue color can be mealuted at 640 nm.

REQUIREMENTS:

1.  Phonal 10 in.(prepare weekly), Liquified Phonal (> 90 % )11.1 ml ethanol 95% (100ml),       sodium nitropruside (0.5%) (State in bottle up to 1 month)

2.  Alkaline citrate 10 In.
    - Trisodium citrate 20 gm.
    - Sodium hydroxide 1 gm
    (Make final vol. 100ml with D/W)

3.  Sodium hypochloride 10 In.
    About 5% available commercially

4. Oxidizing 10 In (prepare fresh)
  - Alkaline citrate 10 In. (100ml)
  - Sodium hypochloride (25ml)

5. Stock ammonia 10 in.
 - NH4CL   (0.0362 gm)
 -D/W (100ml)
  (1ml =1.22mg NH3 )
6. Std. ammonia 10 in.
  -Stock ammonia 50 In (1ml)
  -D/W (199ml)

7. Test tube- (12), Pipettes (1ml & 5ml ), colorimeter with cuvate

PROCEDURE:

-  Take different aliquotes of NH4CL Std. 10 In from 0.1,0.2…..0.5ml.
-  In blank, do not add NH4CL make the final vol. 5ml with D/W. add 0.2ml phenol reagent   in all tubes.
-  add 0.2ml of sodium nitropruside 10 In. in all the 10 in
-  Stopper  the entire bottle with cap & incubate in dark at room temp. For 1 hr.
-  For unknown sample, take 3 aliquotes of 0.2,0.3,0.5ml & proceed in similar way above         ,mealute absorbance of all tubes at 640 nm
-  Prepare STD curve by platting absorbance of Std. against ammonia conc. Of STD.
-  Find out conc. Of unknown sample using STD curve.



RESULT:

1. The conc. of NH3-N in drinking water is …………………………….µgs/ml
2. The conc. of NH3-N in wastewater is …………………….µgs/ml


Comments

Popular posts from this blog

List Of Biotechnology Company (Database Link)

  100x Imaging India Pvt Ltd Abexome Biosciences Private Limted   ABL Biotechnologies Ltd   ABLE(Association of Biotechnology Led Enterprises)   Abbott India   ABS- NOVACELL BioPharmaceuticals India Pvt Ltd   Accelrys Inc.   Accurex Biomedical Pvt Ltd   Accutest Research Laboratories (I) Pvt Ltd   Ace Biomed Private Limited   Ace Instruments Services Pvt Ltd   Actimus Biosciences Pvt Ltd   Actis Biologics Pvt Ltd   Acton Biotech(India) Pvt Ltd   Adam Fabriwerk Pvt Ltd   Advanced Bio-Photonics   Advanced Computer Systems   Advanced Enzyme Technologies Ltd   Advance Microdevices Pvt Ltd   Advanta India Ltd     Advinus Therapeutics Ltd AG Bioteck Laboratories(india) Pvt Ltd     Agappe Diagnostics Pvt Ltd Agastya Biopharm India Ltd   Agharkar Research Institute   Agilent Technologies India Pvt Ltd   Agro Biotech Research Center Ltd ...

Process of Wastewater Treatment Plant

PROCESS OF WASTEWATER TREATMENT PLANT : Wastewater enters the treatment plant First it goes through a fine screen, next to aerated grit chamber, and then enters the primary clarifier. Sludge settled in the primary clarifier is sent to the fermenters and then to digesters. After the primary treatment, wastewater flows into (BNR) bioreactors. The activated sludge is separated in the following secondary clarifier. The clear effluent flows into Ultraviolet (UV), then to River. Settled activated sludge in the secondary clarifier is pumped back to BNR. Excess sludge is pumped into the dissolved air floatation (DAF) unit for thickening. Wastewater is collected in sanitary sewers (a complex network of underground pipes). Upon reaching the treatment plant, the wastewater flows through a series of treatment processes which remove the wastes from the...

Water Analysis : To determine the potability of water by MPN Test

AIM : To determine the potability of water by MPN Test INTRODUCTION: Water which receives animally & human which form a primary source of water borne disease. Direct testing procedures capable of detecting & quantifying the full spectrum of pathogens & identifying their source is time consuming process because of their variable occurrence, survival rate & origin; hence an indicator system has been identified as a best method for evaluating the microbiological quality of water. A fecal coli form test is considered as most reliable test available for detesting   the presence of contamination of an intesting origin, the coli form group comprises all aerobic & facuttative an aerobic, gram –ve   non spirulating, rod shaped bacteria that ferment lactase with gas format within 48hrs at 35 ˚c. REQUIREMENTS: Single strength of sactose bile growth (10 ml) -10 test tube Double strength of sactase bile growth (10 ml) - 5 test tube Water sam...