Water Analysis : To Estimate Amount of Nitrite Nitrogen In Given Water Sample



INTRODUCTION:

Nitrite is an intermediate oxidation state of nitrogen both in the oxidation of ammonia to nitrate & in the reduction of nitrate. Such oxidation & reduction may occur in waste water treatment, water distribution system & natural water. Nitrite can enter a supply system through it use as a corrosion inhibitor in industrial process water.
Nitrite is the actual etiological agent at methemoglobimia. Nitrous acid which is formed from nitrite in acidic solution can react with nitro samines , many of which are known to be carcinogens.

PRINCIPLE:

Nitrite is determined through formation of reddish purple azo dye produced at pH 2.0 to 2.5 by coupling diazotize sulphanilamine with N’ (1- napthyl) ethyl diamine dihydrochloride (NED). The applicable range of the method for photometric measurement is 10-10,000 micro gram NO2/l. Photometric measurement can be made in the range 5 to 50 ยตg N2/l, if a 5cm light path & a green color filter are used. Higher nitrite conc. Can be determined by diluting a sample with nitrite free D/W. The measurement is taken at 543nm using spectrophotometer.

REQUIREMENTS:


  •  Nitrite frees D/W.
  • Water sample.

-          Drinking water &
-          Waste water

  • Color reagent.

        1. 85% phosphotic acid 100 ml. 
        2. Sulfonilamide 10 gm 
        3. Dissolved property in 800ml D/W. 
        4. NED hydrochloride 1 gm. 
        5.  Mix & final vol. 1000ml with D/W.
        6.  Solution is stable for 1 month.
  • When stored in dark bottle in refrigerator.   
  • Stock nitrite solution.  (NaNO2  1.232g)
 (1ml = 250 ยตg N)
-          D/w 1000 ml
-          Preserve with 1ml  CHCl3.
  • Intermediate nitrite solution.
-          Stock nitrite solution 50ml.
-          D/W  250 ml.
(1ml = 50 ยตg N)
  •  Standard (working) nitrite solution.
-          Intermediate nitrite solution 10ml.
-          Make final vol. 1000ml with D/W
(1ml  =  0.5 ยตg N)
-          Prepare fresh.
  •  Test tubes – 11
  • Pipettes  1 ml  & 10 ml
  •  Spectrophotometer & quates.
PROCEDURE:

Take different aliquotes of std. nitrite solution form 0.2, 0.4,…….. 1 ml.
-          In blank do not add std. solution.
-          Prepare 3 aliquotes of unknown sample.
-          Add D/W in all tubes to make final vol. 10 ml.
-          Add 0.2 ml color reagent in all tubes.
-          Incubate all the tubes at room temp. For 10 min.
-          Take O.D. of all tubes at 543nm using blank as a reference.
-          Prepare a std. curve by plotting absorbance of std. against nitrite nitrogen (ยต gms) of std. & find out conc. Of nitrite present in unknown sample.
-          Note down the result & give your conclusion.

Comments

Popular posts from this blog

List Of Biotechnology Company (Database Link)

  100x Imaging India Pvt Ltd Abexome Biosciences Private Limted   ABL Biotechnologies Ltd   ABLE(Association of Biotechnology Led Enterprises)   Abbott India   ABS- NOVACELL BioPharmaceuticals India Pvt Ltd   Accelrys Inc.   Accurex Biomedical Pvt Ltd   Accutest Research Laboratories (I) Pvt Ltd   Ace Biomed Private Limited   Ace Instruments Services Pvt Ltd   Actimus Biosciences Pvt Ltd   Actis Biologics Pvt Ltd   Acton Biotech(India) Pvt Ltd   Adam Fabriwerk Pvt Ltd   Advanced Bio-Photonics   Advanced Computer Systems   Advanced Enzyme Technologies Ltd   Advance Microdevices Pvt Ltd   Advanta India Ltd     Advinus Therapeutics Ltd AG Bioteck Laboratories(india) Pvt Ltd     Agappe Diagnostics Pvt Ltd Agastya Biopharm India Ltd   Agharkar Research Institute   Agilent Technologies India Pvt Ltd   Agro Biotech Research Center Ltd ...

Process of Wastewater Treatment Plant

PROCESS OF WASTEWATER TREATMENT PLANT : Wastewater enters the treatment plant First it goes through a fine screen, next to aerated grit chamber, and then enters the primary clarifier. Sludge settled in the primary clarifier is sent to the fermenters and then to digesters. After the primary treatment, wastewater flows into (BNR) bioreactors. The activated sludge is separated in the following secondary clarifier. The clear effluent flows into Ultraviolet (UV), then to River. Settled activated sludge in the secondary clarifier is pumped back to BNR. Excess sludge is pumped into the dissolved air floatation (DAF) unit for thickening. Wastewater is collected in sanitary sewers (a complex network of underground pipes). Upon reaching the treatment plant, the wastewater flows through a series of treatment processes which remove the wastes from the...

Water Analysis : To determine the potability of water by MPN Test

AIM : To determine the potability of water by MPN Test INTRODUCTION: Water which receives animally & human which form a primary source of water borne disease. Direct testing procedures capable of detecting & quantifying the full spectrum of pathogens & identifying their source is time consuming process because of their variable occurrence, survival rate & origin; hence an indicator system has been identified as a best method for evaluating the microbiological quality of water. A fecal coli form test is considered as most reliable test available for detesting   the presence of contamination of an intesting origin, the coli form group comprises all aerobic & facuttative an aerobic, gram –ve   non spirulating, rod shaped bacteria that ferment lactase with gas format within 48hrs at 35 ˚c. REQUIREMENTS: Single strength of sactose bile growth (10 ml) -10 test tube Double strength of sactase bile growth (10 ml) - 5 test tube Water sam...